2.7 POWER CONNECTION
The projector is a class 2M source of visible and invisible LED radiation. Directly viewing
the LED output with certain optical instruments (for example, eye loupes, magnifiers and microscopes)
within a distance of 100 mm may pose an eye hazard.
DO NOT operate if the AC supply and cord are not within the specified voltage and
power range.
The North American rated line cord is supplied with this projector. For all other regions,
use only a regionally approved line cord, power plug and socket.
DO NOT use a damaged line cord.
2.7.1 Connecting the projector to AC
The input voltage to the projector must be capable of 100-240 VAC. Use only a correctly rated line cord.
NOTE: DO NOT use a line cord or AC supply not in the specified voltage and power range. See Section 5
Specifications for projector power requirements.
1. Connect an approved line cord to the projector’s AC receptacle, located on the Light Module.
NOTE: Use
only the line cord supplied with the projector or a power cord of correct ratings that comply with regional
standards.
2. Connect the 3-pronged end of the line cord to a grounded AC outlet. NOTE: The outlet must be near the
equipment and easily accessible.
2.7.2 Turning the Projector ON
1. Flip the power switch on the LM (Light Module) ON. The projector takes about 2 minutes to initialize.
The status light beside the LED window turns yellow.
2. Using the remote keypad press the Power button, and then the UP arrow.
3. Press one of the input keys on the remote to select and display the image for the source connected in
2.6 Connecting Sources. For more information on the keys available on the remote and their function, refer
to
3.2 Using the Remote Keypad, on page 3-1.
2.7.3 Disconnecting the projector from AC
DO NOT turn the main power switch to the OFF position or disconnect the projector
until the cooling fans have stopped.
Stop the projector. After the internal cooling fans stop, move the main power switch on the light module to the
OFF position. This gives the light module enough time to cool. Disconnect the line cord from the wall outlet.
Refer to
Section 5 Specifications for complete details on all power requirements for the projector.