26 of 27 LX505/605 RS232 Codes-Basic Technical Reference Information
020-000241-01 Rev. 1 (02-2010)
7.5 INPUT MODE READ COMMAND
7.6 LAMP TIME READ COMMANDSETTING READ COMMAND
Command “CR1” [CR]
Detail Get currently selected Input No.
Response
Acceptable “%1” [CR]
%1
”1” = Input 1 is selected.
“2” = Input 2 is selected.
“3” = Input 3 is selected.
“4” = Input 4 is selected.(only for Networking-capable models)
Unacceptable “?” [CR]
Command “CR3” [CR]
Detail
Get total lamp running hours.
*return lamp operating time multiplied by the given coefficient (not actual used time)
Response
Acceptable “%1” [CR]
%1
Display Lamp running hours with 5 digit numbers.
Example:
“00410” [CR] ---------- 410 hours
Unacceptable “?” [CR]
Command “CR4” [CR]
Detail Get screen setting status such as Ceiling/Rear.
Response
Acceptable “%1” [CR]
%1
“11” [CR] = Normal Screen Setting
“10” [CR] = Picture is top/bottom reversed. (Status: Rear & Ceiling
ON)
“01” [CR] = Picture is left/right reversed. (Status: Rear ON)
“00” [CR] = Picture is top/bottom and left/right reversed. (Status:
Ceiling ON
)
Unacceptable “?” [CR]