LX505/605 RS232 Codes-Basic Technical Reference Information 25 of 27
020-000241-01 Rev. 1 (02-2010)
“24” [CR]
Status: Power-Save Cooling Down in process
This indicates Power Management in the Setting menu is enabled and Power-Save Cooling Down operation is in
process.
During this time, any Functional Execution Command is invalid.
In this Power-Save Cooling Down function, the status moves to Power Save after the given Cooling down operation.
“04” [CR]
Status: Power Save
This indicates it moves to Power-Save status by Power Management function as set in the Setting menu.
“21” [CR]
Status: Cooling Down in process after OFF due to Lamp Failure
When the projector is turned off due to lamp failure, it automatically starts Cooling Down operation. The pro-
jector returns “21” [CR]. “21” [CR] has been kept during Cooling Down operation.
“81” [CR]
Status: Standby after Cooling Down due to Lamp Failure
The projector has recovered from Lamp Failure status. When the projector enters Standby status after Cool-
ing Down operation invoked due to lamp failure, it returns “81”. This indicates the status turns to Standby
due to lamp failure. This status continues until the next operation is started; when Power On is executed, the
projector clears the information of Lamp Failure and normal operation starts.
“2C” [CR]
Status: Cooling Down in process due to Shutter management function
This indicates it has moved to Cooling down status according to the setting of Shutter Management function in setting
menu. During this time, Functional Execution Commands are not accepted.
“8C” [CR]
Status: Standby after Cooling Down due to Shutter management function.
This value is returned when Cooling Down operation due to Shutter management has been completed and the status
has been moved to Standby. The status is kept until the next operation starts. When projector is turned on again, it
cancels the last status and starts normal operation.