Christie DWX600-G User Manual Page 43

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 42
G Series User Manual
020-000648-01 Rev. 3 (02-2014)
Section 4: Operation
4-14
y
Manual Adjustment
1. Adjust color slide bars and judge image color by eye or meter. A user-
dened color “adjustment” can be applied.
2. Use this submenu if you do not have specic color coordinates in
mind and will judge color performance by eye or meter. As for Meter
Adjustment, each color control actually denes new x/y coordinates for
that color and changes its hue. The main colors (red part of red, green
part of green and blue part of blue) adjust the intensity of that color
component, while the modifying colors (e.g. green part of red and blue
part of red) modify the x and y value and change the hue of that color.
At the same time the main colors also are used to control the color of
the white point.
Hot-Key Settings
Assign a different function to the hot-key on the remote control by highlighting
the function in the list and pressing ENTER. Choose a function that does
not already have a dedicated button, and assign the hot-key to that function,
allowing you to quickly and easily use the chosen function.
Service
y
Projector Info: Display current projector settings (read-only).
y
Factory Reset: Restore all settings to their default value. It will not reset
network but it will reset RS232.
y
Test Pattern: Choose the desired internal test pattern to display, or select
OFF to turn off a test pattern.
y
Color wheel Index (2x): Set Color wheel index to Speed 2X. This setting
only needs to be used when the Main Board is changed, and should be
adjusted to optimize picture quality.
y
Color wheel Index (3x): Set Color wheel index to Speed 3X. This setting
only needs to be used when the Main Board is changed, and should be
adjusted to optimize picture quality.
y
Error log: Show the projector error log for debug.
y
Mode Adjustment: Fine tune the H and V start position for a signal in the
EDID timing table and record the values in the system to override the
timing table. The settings must be “Saved to Record” before exiting the
menu, or they will be lost. To revert to original timing table settings, each
setting must be manually cleared. Factory Defaults will not clear these
override settings.
y
Light Sensor: Calibrate the Light Sensor for use with the Constant Intensity
lamp mode, which allows the projector to be set for constant brightness. If
the Light Sensor has not been calibrated, Constant Intensity mode will be
disabled. Light Sensor calibration should be repeated when new lamps are
installed.
Page view 42