Section 7: Specifications
M Series User Manual 7-3
020-100009-08 Rev. 1 (05-2013)
7.1.9 Color Temperature
7.1.10Convergence
Convergence zones A, B, C are as defined in Figure 2. Zone A has a diameter ¼ of the image height. Zone B
has a diameter of full image height. All specified convergence errors are between any two colors after a
minimum warm-up of 30 minutes.
Convergence is specified with a 1.4-1.8 HD lens (part number 118-100112-01) in the 1.4:1 position with zero
offset. Bore-sight alignment must be adjusted for zero angular error. (Note: convergence error includes the
effects of lateral color in the projection lens. Measurements must be done on horizontal and vertical test pattern
lines that intersect the center of the image).
White Default CCT (without YNF) 7700 K ±2000 K 350W, 450W Lamp
8900 K ±2000 K 200W Lamp
White YNF CCT (with YNF activation, electronically
corrected)
6500 K ±1000 K
Range of Adjustment 3200 K - 9300 K
Tracking (deviation from normal over full range from 10
to 100 IRE)
±500 K max
Stability (during rated lamp life) ±500 K max
MEASUREMENT AREA MAXIMUM CONVERGENCE ERROR (PIX-
ELS)
Zone A 1/4
Zone B 1/2
Zone C 3/4
(Figure applicable to both 1080p and SXGA+)