PARTS & MODULE REPLACEMENT
CP2000-X Parts & Module Replacement 21
5) Remove four 5/32” hex screws securing the pump mounting bracket to the
base the projector. The interior screw nearest the heat exchanger is very
difficult to reach.
6) To remove the pump assembly,
tilt it toward the front and middle
of the projector—this may take
several tries, but the entire heat
exchanger/pump assembly can be
removed via the igniter door
opening.
Re-installation:
PROPER ROUTING TO LIGHT
ENGINE:
At the underside of
the projector, make sure to re-
connect the hoses correctly:
Heat exchanger to red
(CP2000-X lamp side)
Reservoir to blue
(CP2000-X air filter side)
FILLING: The system is
subject to air locks upon
filling, particularly if hose
lines are significantly curved.
For best results, fill before
securing the new cooling
system in the projector—
spread lines out as flat and
straight as possible before
adding liquid coolant.
Eliminate any air locks—
liquid must be continuous,
with no gaps or bubbles.
IF A SINGLE COOLING
COMPONENT WAS REPLACED:
To fill a system already installed within the
projector (for example, when you have replaced only the pump):
Figure 29. Cooling Components
Out
Figure 30. Proper Hose Reconnection