Aperture – Adjusts the optical aperture inside the projector. The optical
aperture inside the projector controls the diameter of the opening to the lens,
controlling the amount of light leaving the projector. With a fully open
aperture, the maximum amount of light passes through for maximum
brightness. Reduce the aperture diameter to increase contrast ratio. Enabled
when Lamp Mode is set to Intensity. Depending on the projector model,
either the up and down buttons or the slider are enabled to adjust settings.
NOTE: If the selected projector can store the aperture setting, then this
control displays as a slider.
Lamp History
Lists the lamps most recently installed and recorded in the projector. Lamp
history automatically updates whenever you record a new lamp serial
number—the new lamp is added to the bottom of the list.
4.5.5 PIP (Picture-in-Picture) Tab
Figure 4-13 PIP
Picture in Picture
Enable Picture in Picture – •Activates the PIP window and enables the
controls on the tab. PIP functions only when you have an active signal
and are not running a test pattern. If you have no active signal the
following warning is displayed, No Active Video Signal/Image Settings
Controls Disabled and the PIP Image controls are disabled.