Appendix A: Serial API Commands
SUBCODE DESCRIPTION OF USE
Cxxx Replace Cxxx with the channel number. Valid range is 101-164.
NONE Set lamp mode for the current channel.
EXAMPLES:
(LPM 0) Set Constant Power mode for current channel
(LPM “Constant Power”) Set Constant Power mode for active channel
(LPB+C101 1) Set intensity mode for channel 1
(LPM?) Get Lamp mode for active channel
Lamp Power (LPP)
Set lamp power to be used when in Constant Power mode. NOTE: This command can only be used to update the
current lamp file. Changing the lamp power for the current channel will change the lamp power for any channel
using the same lamp file.
SUBCODE DESCRIPTION OF USE
Cxxx Replace Cxxx with the channel number. Valid range is 101-164.
MINI Get nominal minimum lamp power for the current lamp. Read-only value
NONE Set lamp power for the current channel.
EXAMPLES:
(LPP 2500) Set lamp power to 2500 for current channel
(LPP+C102 2000) Set lamp power to 2000 for channel 2
(LPP+C102?) Get the lamp power for channel 2
Lens Vertical Offset Adjustment (LVO)
Adjust lens offset to specific vertical position with a specific direction. NOTE: This command can only be used to
update the current ILS file. Changing the vertical offset for the current channel will change the vertical offset for
any channel using the same ILS file.
Use command without subcode:
If ILS is ON, motor will move to specified steps and save data to the active channel.
If ILS is OFF, motor will move to specified steps. Do not save data to the active channel.
SUBCODE DESCRIPTION OF USE
BACN Motor backlash in negative direction. Read-only.
BACP Motor backlash in positive direction. Read-only. Set only command.
CALB Calibrate travel range and backlash on specified. Only valid parameter for this command is 1. Set only
command.
Cxxx Replace Cxxx with the channel number. Valid range is 101-164.
NONE Moving lens mount to a specified vertical position with a specified direction.
RNGN Motor moving range in negative direction. Read-only.
RNGP Motor moving range in positive direction. Read-only.
RSET Move motor to the center flag then move back to current position. Only valid parameter for this command
is 1. Set only command.
STRT Start motor moving in specified direction, where direction can be (-1, 1). Write-only for v1.3 or newer.
STOP Stops the motor. Write-only for v1.3 or newer.