Christie CP 2210 User Manual Page 146

  • Download
  • Add to my manuals
  • Print
  • Page
    / 164
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 145
A-20 CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Appendix A: Serial API Commands
System Status (SST)
R
etrieve the various system status groups.
SUBCODE DESCRIPTION OF USE
ALRM Returns a summary of any active alarms
CONF Returns configuration data - model, sn, build date, etc
COOL Returns cooling data - cooling fans, air flow, etc
HLTH Returns system health
INTE Returns interlock data
LAMP Returns lamp operational data.
NONE Returns information on all status groups, with one message per item.
PERI Returns peripherals data - Cine-IPM, etc
SECU Returns security data
SERI Return serial numbers
SIGN Returns signal data - freq, etc.
SYST Returns system data - power, hours of use, shutter open, etc
TEMP Returns temperature data
VERS Returns version numbers
EXAMPLE:
(SST+ALRM?) returns (SST+ALRM!000 002 “101” “Prism temperature”) where parameters are:
P1=index number,
P2=error level,
P3=value,
P4=description.
Error level is:
0=no errors or warnings,
1=warning,
2=error,
3=error and warning
Stop DLP Communication (STP)
Stop communications to DLP
®
Cinema Electronics temporarily, i.e. for DLP software upgrading.
SUBCODE DESCRIPTION OF USE
NONE 0 - restart DLP communications;
1 - stop DLP communications.
EXAMPLES:
(STP 0) Restart DLP communication
(STP 1) Stop DLP communication
(STP?) Request current state. Example response is (STP!000)