Section 2: Basic Operation
CP2000-M/MR Setup Guide 2-3
020-100205-03 Rev. 1 (05/09)
Cool the Lamp Completely
The arc lamp operates at a high pressure that increases with temperature. Failure to allow the lamp to
sufficiently cool prior to handling increases the potential for an explosion causing personal injury and/
or property damage. After turning the lamp OFF, it is crucial that you wait at least 15 minutes
before
disconnecting AC and opening the lamp door. This provides enough time for the internal lamp cooling
fans to properly cool the lamp. Cool the lamp completely before handling. Again, always
wear
protective clothing. For all other precautions critical for safe removal and replacement of the lamp,
refer to 4.1
Lamp Replacement.
2.2 POWERING UP THE PROJECTOR
This is a manual power-up procedure. Some installations
may include an automation system that controls lamp
ignition in conjunction with other theatre variables.
The projector is powered by 200-240VAC. The switching
ballast provides a well regulated DC current (up to 85 amps)
with a maximum ballast power of 2.1kW. The power output
from the ballast is controlled by the Projector Control
Module (PCM), via a dedicated ‘RS232’ connection from the
motherboard to the ballast. A switch selectable secondary
100-240VAC inlet is provided, allowing the main electronics
to be powered separately, via a universal 100-240VAC UPS.
The main ballast is powered through the main 200-240VAC
inlet. A discrete AC switch above the 2 inlets (Figure 2-1)
allows the user to select whether the main electronics are
powered from the main inlet (requiring only 1 power cord to
supply the entire unit), or the secondary inlet supplied by the UPS, via an additional line cord (not
provided).
1. Connect the line cord to the AC receptacle at the lower-left rear corner of the projector and to
proper AC - the outlets must be near the equipment and easily accessible. IMPORTANT! Use the
line cord provided with each projector. DO NOT compromise safety by using other connectors.
DANGER
Lamp may explode causing bodily harm or death. Always wear protective clothing
whenever lamp door is open or while handling lamp. Ensure those within the vicinity of
the projector are also suited with protective clothing.
Never attempt to access the lamp while the lamp is ON. Wait at least 15 minutes after
the lamp turns OFF before powering down, disconnecting from AC and opening the
lamp door.
WARNING
Do not attempt operation if the AC supply is not within the rated voltage range,
as specified on the license label (found on the back of the projector).
Always power down the projector before unplugging the AC line cord. Wait 15
minutes for the main exhaust fan to turn OFF and for the lamp to cool
sufficiently before unplugging.
FIGURE 2-1 AC RECEPTACLE