Section 7: Specifications
CP2000-M/MR User Manual 6-3
020-100205-03 Rev. 1 (05/09)
6.3 POWER REQUIREMENTS
6.3.1 Standard Mode (uses line cord provided)
Voltage Range: 200 - 240 VAC
Line Frequency: 50 Hz - 60 Hz nominal
Inrush Current: < 85 A max.
Current Consumption: 16 A max. (at 200 VAC)
Power Consumption: 3200 W max.
Current Rating of AC Input: IEC-320-C19/20A (required by regulatory)
Line Cord Plug Type NEMA 6-20P
6.3.2 UPS (Uninterruptible Power Supply) Mode
Activation Discrete switch above power inlet cord(s)
UPS Inlet Connector IEC-320-C13/10A, 240VAC
(rating for powering main electronics on projector)
Inlet Rating 100-240VAC, 8A (refer to license label)
Lamp Power Supply Inlet Rating
(also required) IEC-320-C19/20A (required by regulatory)
6.4 LAMPS
Type CDXL-20SD, Xenon Short Arc Lamp
Power (software adjustable) 1000W min. - 2000W nom. - 2100W max.
Average Life (See Notes 1, 2) 1000 hours @ 2000W
Warm-up time to full brightness 20 minutes max.
Wait time between lamp strikes (see Note 3) 2 minutes min.
Type CDXL-18SD, Xenon Short Arc Lamp
Power (software adjustable) 1000W min. - 1800W nom. - 1980W max.
Average Life ( See Notes 1, 2) 1500 hours @ 1800W
Warm-up time to full brightness 20 minutes max.
Wait time between lamp strikes (see Note 3)
NOTES: 1) Based on use at nominal rated power; operating at greater than nominal power reduces
lamp life. 2) End of life is defined as the point where the amount of flicker is above the manufacturer’s
threshold (1.2V); or the lamp fails to ignite 3 out of 5 successive attempts; or brightness is <50% of
initial brightness. Duty cycle 2 hours ON/0.5 hours OFF. 3) Hot re-strike (less than the minimum time
between strikes) reduces lamp life; therefore it is strongly NOT recommended.