2-4 CP2000-M/MR Setup Guide
020-100205-03 Rev. 1 (05/09)
Section 2: Basic Operation
For all other regions, ensure a line cord, power plug and socket that meet the appropriate rating
standards are used. When the main inlet is used the AC switch must be set to A only (Figure 2-2).
2. An optional feature to power all electronics through a UPS is available using the secondary inlet.
When the secondary inlet is used the AC switch must be set to the A + B (Figure 2-2). This feature
enables users to power all electronics through a UPS, which minimizes downtime in the event of a
brief power outage.
FIGURE 2-2 CONNECTING TO POWER
3. From the CDP, press Power ON and hold for 2 seconds to fully power up the projector. This takes
approximately 2 minutes in preparation for igniting the lamp. NOTE: If the Lamp ON key is
selected while the projector is in STANDBY mode, power is first turned ON and then the lamp is
ignited.
4. From the CDP, press Lamp ON and hold for 2 seconds to turn the lamp and lamp fans ON. Once
pressed the green ON and amber READY status LEDs flash slowly until the lamp is ignited, at
which point the READY LED turns OFF and the ON LED turns solid.
If Lamp Fails to Ignite: If a safety interlock switch is open (i.e., lamp door open), the lamp cannot be
struck until the interlock problem is resolved. The Error LED on the CDP is illuminated red and
flashing, and the LCD Status Display Window displays ERROR:StrikeFail. If the lamp fails to
ignite even though the interlock system is OK, the projector automatically attempts ignition using
100% of the maximum power acceptable for the installed lamp. If this fails, a new lamp is likely
required.