Christie CP2000-M Setup Guide Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
2-18 CP2000-M/MR Setup Guide
020-100205-03 Rev. 1 (05/09)
Section 2: Basic Operation
To enable ILS:
1. From the Main menu select 1 of
the available channels.
2. Enable Test Patterns to bring up a
test pattern.
3. Select the ILS button from the
Main menu to launch the ILS
screen.
Select Automatic ILS to
automatically apply the per
channel settings.
To edit active channel ILS settings:
1. Ensure Automatic ILS is checked.
2. Adjust the focus, horizontal (X) and vertical (Y) offset or zoom one step at a time by clicking the
applicable button or hold the button down for continuous movement. If you hold a cutton down, a
pending message will display ntil you release the button. NOTE: This over-writes the intelligent
lens system settings.
To temporarily alter the active channel ILS settings:
1. De-select the Automatic ILS checkbox.
2. Adjus the focus, horizontal (X) and vertical (Y) offset, and zoom. Note: This does not over-write
the system settings for the ILS.
3. To revert back to the ILS settings, check Automatic ILS.
Start Features or PresentationsTo start a different feature or presentation, click its corresponding
display Channel button. NOTE: By clicking a channel button, test patterns and automatically turned
OFF to present show content.
FIGURE 2-10 INTELLIGENT LENS SYSTEM
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 73 74

Comments to this Manuals

No comments