Section 2: Installation & Setup
CP2000-SB User Manual 2-15
020-100162-04 Rev. 1 (05-2009)
Special Adjustments for Some AC Supplies
AC levels can vary depending on region. Check the following when installing.
NOTES: 1) Requires voltmeter for up to 400 VAC. 2) Consult the Interconnect Drawing in pedestal.
JUMPER FROM IGNITER TERMINAL 2:
As set from the factory, the igniter jumper
located on terminal 2 connects to T2. This
configuration is used when 207-265 VAC
are present (as it is for most countries). If
you find your incoming AC is below 207
VAC, connect terminal 2 jumper to T1
instead.
If AC between terminals 2 and 3 is
207-265, connect terminal 2 to T2
(factory default).
If AC between terminals 2 and 3 is
180-207, connect terminal 2 to T1.
See Figure 2-21.
BALLAST 115 VAC TAPS:
Ensure your nominal line between the
terminals labeled 115V and COMMON
(or 0V) is within 10% of 115 VAC. See
Figure 2-22.
If your measurement at the 115V ter-
minal is 126.5V or more, move the 115V wires to the tap labeled –10%.
If your measurement at the 115V terminal is 103.5V or less, move the 115V wires to the tap labeled
+10%.
Figure 2-21 Check Voltage and Position Jumper
Figure 2-22 Check Voltage Between 115V and Common (“0V”)