Christie CP2000-X User Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 164
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
INSTALLATION AND SETUP
CP2000-X User Manual 2-19
020-100031-01 Rev . 1 (03-2009)
1. Check lamp cradle (anode end) location for your lamp
For 4.5 or 6.0 kW lamps, the lamp
cradle must be as far forward as
possible (factory default).
For 2.0 or 3.0 kW lamps, move the
cradle to the rear position, i.e.,
approximately 1” closer to the
reflector. See Figure 2.22.
2. Install Lamp
See 6.4, Replacing the Lamp & Filter,
Steps 7-11. Observe all warnings, and wear
protective clothing and shielding.
Don’t forget to properly mark the “Lamp
Installed” label on the lamp door to
indicate current lamp size. Also set the
Lamp Type in the TPC Lamp menu
(service/installer login required) before
turning on the projector.
Extractor Fan and Duct
For any CP2000-X with any lamp, install
the Christie extractor fan and duct to pull
warm exhaust air from the projector at a
minimum rate of 450 CFM (for 2 or 3 kW
lamps) or 600 CFM (for 4.5 kW or higher lamps). Use either the 6-in. or the 6-ft.
duct in one of the configurations shown in Figure 2.23. below:
Figure 2.23. Extractor Fan Configurations
(MANDATORY SAFETY CABLING NOT SHOWN)
Figure 2.22. Move cradle back
for 2.0 or 3.0 kW lamps
Cooling
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 163 164

Comments to this Manuals

No comments