Christie CP2000-X Setup Guide Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
Section 2: Installation & Setup
2-24 CP2000-X SETUP GUIDE
020-100059-01 Rev 1. (03/08)
When the ballast has been properly configured (see 2.7, Connecting the Ballast)
and connected to the projection head, connect its integral line cord to AC. Then:
SET LAMP TYPE:
WARNING
Qualified Service Technician/Installer is required.
HAZARD
Explosion hazard. Keep the projection head OFF
until you have defined which lamp type is installed.
Before powering up
the projector and
igniting the lamp, the
installer must define,
in projector memory,
which size lamp is
installed; otherwise
you risk severely
overdriving or
underdriving a lamp.
At the TPC, go to the
Admin: Lamp menu
(password required).
Enter the size of the
lamp currently
installed in the
projector (factory
default = 2.0 kW).
See User’s Manual -
Section 3, Operation
if you need help using the TPC menus. Also record the lamp type on the “Lamp
Installed” label attached to the lamp door.
SET CABLE LENGTH: Still in the Admin: Lamp menu (see Figure 2.30), use the
“Cable Length (m)” text box to record the length of high-voltage DC cables
connected between your lamp ballast and projection head. This value regulates
the voltage drop that occurs over distance, and ensures that adequate voltage
reaches the lamp. This setting may have to be changed from its last use,
particularly in a projector rented for temporary installation. Adjustment range is
2-30m (6½-100 ft.).
POWER-UP: Power up the CP2000-X system as described in User’s Manual - 3.2
Power-up Procedure.
2.8 Initial Power-
Up
Figure 2.30 Lamp Type and Cable Length
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 63 64

Comments to this Manuals