CP2000-X SETUP GUIDE 6-3
020-100034-01 Rev 1. (03/08)
7 kW 3-Phase Ballast (38-814001-01)
Nominal Voltage per φ
• 208 VAC (North America / Japan)
• 400 VAC (Europe)
Nominal Operating Range • 200-230 ± 10% (North America / Japan)
• 380-415 ± 10% (Europe)
Line Frequency 50-60 Hz nominal
Inrush current (max.)
note: excluding lamp <50 A
Current consumption per phase (max.) @ 6.6
kW
• 28 A @ 208 VAC (North America / Japan)
• 16 A @ 400 VAC (Europe)
Power consumption (max.) • 14.4 kVA (9.1 kW), all regions
Current rating (continuous) of 3-phase AC input
at breaker
30 A, all regions
Breaker rating 50 A
BALLAST OUTPUT TO PROJECTION HEAD
Operating voltage range 18-46 VDC
Start-up voltage (open current) 125-155 VDC
Operating current range 50-180 A
Ripple 1% max @ 25°C
Control ports See Control Port and Interlock Port on
previous page
CXL/CDXL Lamps (kW) Current Range (amps) Lamp Life (warranty hrs.)
CDXL-20 (2.0) 66-88 1200 full / 2400 pro-rated
CXL/CDXL-30 (3.0) 82-120 720 full / 1440 pro-rated
CXL/CDXL-45 (4.5) 112-150 60 full / 900 pro-rated
CXL/CDXL-60 (6.0) 126-170 50 full / 500 pro-rated
* NOTE: Current range shown includes “over-drive” of approximately 10% more than the
original lamp rating.
Type
Xenolite
®
Stand-by lamp power level for 4-6 kW 50% of lamp’s maximum current rating
Stand-by lamp power level for 2-3 kW 75% of lamp’s maximum current rating
Motorized adjustment of position 3-axis, 0.25” range for each
Recommended screen widths:
2.0 kW = 5 ft. max.
3.0 kW = 55 ft. max.
4.5 kW = 65 ft. max.
6.0 kW = 75 ft. max.
All screen sizes approximate and assuming 1.5 screen gain if <70 ft., and 1.8 screen gain if >70 ft.
70 dBA maximum (NOTE: Does not include customer-supplied external
extractor fan.)
• UL 60950-1 and CAN/CSA C22.2. No. 60950-1-03 1
st
edition, bi-national
• IEC 60950-1:200
FCC CFR47, Part 15, Subpart B, Class A — Unintentional Radiation
CISPR 22: 2003 +A1:2004 / EN55022: 1998 +A2:2003, Class A
Information Technology Equipment
CISPR 24:1997 / EN55024:1998 +A1:2001 +A2:2003 EMC Requirements
Information Technology Equipment
Temperature 10°C to 35°C (50°F to 95°F)
Humidity (non-condensing) 20% to 80%
Altitude 0 – 3000 meters
Lam
p
s h
Audible Noise h
Safet
y
h
EMC Emissions h
EMC Immunit
y
h
O
p
eratin
g
Environment h
Page view 62
1 2 ... 58 59 60 61 62 63 64