Section 4: Maintenance
CP2000-X SETUP GUIDE 4-3
020-100034-01 Rev 1. (03/08)
Cool the Lamp Completely
The arc lamp operates at a very high pressure that increases with temperature.
DANGER
Failure to allow the lamp to sufficiently cool prior to
handling, increases the potential for an explosion causing
personal injury and/or property damage.
After turning the lamp off, it is crucial that you wait at least 10 minutes before
turning off the rest of the projector breakers, disconnecting AC and opening the
lamp door. This provides enough time for the internal lamp cooling fans to
properly cool the lamp. Cool completely
before handling. Again, always wear
protective clothing!
WARNINGS
• Never attempt to access the lamp while the lamp is on
• Wait at least 10 min. after lamp shut-off before powering
down, disconnecting from AC and opening the lamp door.
DANGER
SHOCK HAZARD. Disconnect projection head and ballast
from AC before opening the lamp door.
For all other precautions critical for safe removal and replacement of the lamp,
refer to 4.4. Replacing the Lamp & Filter.
The high-intensity lamp and electronics rely on a variety of cooling components
to reduce internal operating temperatures. Regular checking and maintenance of
the entire cooling system is critical to prevent overheating and sudden projector
failure, and helps to ensure reliable operation of all projector components over
time.
Vents and louvers in the projector covers provide ventilation, both
for intake and exhaust. Never block or cover these openings. Do
not install the projector near a radiator or heat register, or within
an enclosure.
It is recommended that you replace the air filter (located on the lamp side of the
projection head) whenever you replace the lamp—or sooner, in dusty or dirty
environments. A clogged filter reduces air flow, and can lead to overheating and
failure of the projector. Check monthly.
See 4.4, Replacing the Lamp & Filter
for instructions. It is also recommended that you visually check the laminar
airflow device (LAD) located nearby. The LAD should be nearly white or light
grey in color.
The liquid cooler system circulates liquid to and from the DMDs in the CP2000-
X projection head, keeping their operating temperature at an acceptable level.
Periodically check the coolant level visible by removing the igniter grille (rear
side grille adjacent to the side input panel)—check for 1) leaks and 2) proper
liquid level.
4.2 Maintaining
Proper Cooling
Ventilation h
Air Filte
r
h
Li
q
uid Coole
r
h