Page view 28
Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 8-1
020-000046-02 Rev 2 (07-2011)
8 Functional Execution Command
8.1 Format
The PC issues a command in the format below:
Pattern 1: CF_Command [CR]
Pattern 2: CF_Command_” %1 [CR]
CF_: Header
Command: String
%1: Parameter (String)
_: Space (To separate the Command and a Parameter)
The projector decodes the received command and when it gets ready to receive another command, it
returns the response.
“000” [CR]: (0x06, 0x0D) When receiving Functional Execution Command
nnn” [CR]: Except “000”, when it cannot execute commands for any specific reason.
For detail, see 7. Error Code Table
.
?” [CR]: When the received data cannot be decoded
8.2 Transfer Example
When setting the projector’s total dots to 1344 by Expand Command.
PC → PJ: “CF_TDOTS_1344” [CR]
PC ← PJ: “000” [CR] - Acceptable
Page view 28