Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 8-19
020-000046-02 Rev 2 (07-2011)
8.7.5 CF_CEIL Command
Command
“CF_CEIL_%1” [CR]
%1
“ON” - Set Ceiling to ON
“OFF” - Set Ceiling to OFF
Detail
Set/Cancel Ceiling (valid only when in the normal Power ON status).
When Ceiling is set to ON, the image is left/right as well as
top/bottom reversed.
The status set by this command is stored in EEPROM, and the
setting remains effective after the power is turned to ALL OFF
status.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.7.6 CF_REAR Command
Command
“CF_REAR_%1” [CR]
%1
“ON” - Set Rear to ON
“OFF” - Set Rear to OFF
Detail
Set/Cancel Rear (valid only when in the normal Power ON status).
When Rear is set to ON, the image is left/right reversed.
The status set by this command is stored in EEPROM, and the
setting remains effective after the power is turned to ALL OFF
status.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
Comments to this Manuals