Status Read Commands
9-34 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
9.11.7 CR_TEMPFAIL Command
Command
“CR_TEMPFAIL” [CR]
Detail
Get the temperature inside the projector when the abnormal status
occurs.
It is possible to get the temperatures for more than one sensor all at
once if it is applicable.
Response Acceptable
“000_%1” [CR]
%1
Example: “_31.5F”[CR] _ indicates a space. When
the temperature goes under 0, the first character is
“-”, not a space, as in “-05.5F”.
With more than one temperature sensors installed,
projector returns the responses for each sensor in a
row.
Example: “_31.5F_35.2S” [CR]
The first data indicates sensor 1 data, then one
space, and sensor 2 data is followed. Last character
in each data indicates the sensor’s status.
In the abnormal temperature - “F”
In the safe level of temperature -“S”
Neither in or close to the abnormal temp. -“N”
The second example above indicates that the
temperature detected by sensor 1 is 31.5 which
means in the abnormal temperature, and at sensor 2
is 32.5 degrees which is in the safe temperature.
When the abnormal temperature status is not
occurred the data should be “_00.0S”.
When the projector is reset, “_00.0S” is set.
Every time abnormal temperature status is detected,
it renews the data and returns it.
It only returns the renewed data of the latest
abnormal temperature and the previous data is
cleared.
Unacceptable
“?” [CR]
9.11.8 CR_SERIALNO Command
Command
“CR_SERIALNO” [CR]
Detail
Get value of the serial number.
For Dealer
Response Acceptable
“000_%1” [CR]
%1
Eight digits of alphanumeric characters
Unacceptable
“?” [CR]