Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 9-29
020-000046-02 Rev 2 (07-2011)
9.10.17 CR_PJLOCKNOW Command
Command
“CR_PJLOCKNOW” [CR]
Detail
Get actual setting status of PIN code lock
Response Acceptable
“000_%1” [CR]
%1
“LOCK” - PJ is locked PIN code lock is set to
ON1/ON2 on the menu and PJ PIN code is not
entered, therefore PJ is actually locked.
“FREE” - PJ is unlocked (either A or B) A) PJ lock is
set to OFF on the menu B) PJ lock is set to ON1/ON2
on the menu, but PIN code Lock mode is canceled
because PJ PIN code is entered.
Unacceptable
“Error Code” [CR]
9.10.18 CR_PJLOCMENU Command
Command
CR_PJLOCKMENU” [CR]
Detail
Get ON/OFF setting status of PIN code lock on menu
Response Acceptable
“000_%1” [CR]
%1
“ON1” - PIN code lock ON 1 is set on the menu
“ON2” - PIN code lock ON 2 is set on the menu
“OFF” - PIN code lock OFF is set on the menu
Unacceptable
“Error Code” [CR]
9.10.19 CR_FILH Command
Command
“CR_FILH” [CR]
Detail
Get Filter used time
Response Acceptable
“000_%1” [CR]
%1
“00000 - 99999”
Unacceptable
“Error Code” [CR]
9.10.20 CR_FILCOND Command
Command
“CR_FILCOND” [CR]
Detail
Get status of filter clog
Response Acceptable
“000_%1” [CR]
%1
“CLOG” = Filter is clogged
“WARN” = Filter is nearly clogged
“CLEAN” = Filter is not clogged
Unacceptable
“Error Code” [CR]