Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 9-21
020-000046-02 Rev 2 (07-2011)
9.8.4 CR_REAR Command
Command
“CR_REAR” [CR]
Detail
Get setting status of Rear function
Response Acceptable
“000_%1” [CR]
%1
“ON” - Rear projection is enabled
“OFF” - Rear projection is disabled
Unacceptable
“Error Code” [CR]
9.8.5 CR_VSCALE Command
Command
“CR_VSCALE” [CR]
Detail
Get setting status of V scale
Response Acceptable
“000_%1” [CR]
%1
“-32”
”035”
Unacceptable
“Error Code” [CR]
9.8.6 CR_VPOS Command
Command
“CR_VPOS” [CR]
Detail
Get setting status of V Position
Response Acceptable
“000_%1” [CR]
%1
“-15”
”015”
Unacceptable
“Error Code” [CR]
9.8.7 CR_HSCALE Command
Command
“CR_HSCALE” [CR]
Detail
Get setting status of H scale
Response Acceptable
“000_%1” [CR]
%1
“-32”
”035”
Unacceptable
“Error Code” [CR]
9.8.8 CR_HPOS Command
Command
“CR_HPOS” [CR]
Detail
Get setting status of H Position
Response Acceptable
“000_%1” [CR]
%1
“-15”
”015”
Unacceptable
“Error Code” [CR]