Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 9-31
020-000046-02 Rev 2 (07-2011)
9.10.24 CR_TESTPAT Command
Command
“CR_TESTPAT” [CR]
Detail
Get setting status of Test pattern
Response Acceptable
“000_%1” [CR]
%1
“COLOR” - Color bar is displayed
“GRAD1” - 16step(white→black) is displayed
“GRAD2” - 16step(white←black) is displayed
“GRAD3” - 16step(white↓black) is displayed
“GRAD4” - 16step(white↑black) is displayed
“WHITE” - All white is displayed
“BLACK” - All black is displayed
“CROSS” - Cross is displayed
“OFF” -Test pattern display is not displayed
Unacceptable
“Error Code” [CR]
9.11 Other Status Read Commands
9.11.1 CR_STATUS Command
Command
“CR_STATUS” [CR]
Detail
Get operating status of Projector Same as “CR0” in basic command
except error code follows it.
Response Acceptable
“000_%1” [CR]
%1
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to abnormal
temperature
“88” =Standby after Cooling Down due to abnormal
temperature
“02” = Invalid RS-232C Command
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after turned Off due
to lamp failure
“81”
Standby after Cooling Down due to lamp
failure
“2C” = Cooling Down in process after Power Off due
to Shutter management
“8C” = Standby after Cooling Down due to Shutter
management