Christie LW600 User Manual Page 90

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 89
Status Read Commands
9-28 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
9.10.13 CR_SHUTRCPROT Command
Command
“CR_SHUTRCPROT” [CR]
Detail
Get status if Shutter can be controlled by R/C
Response Acceptable
“000_%1” [CR]
%1
“ON” - Shutter is not controllable by R/C
“OFF” - Shutter is controllable by R/C
Unacceptable
“?” [CR]
9.10.14 CR_SHUTKEYPROT Command
Command
“CR_SHUTKEYPROT” [CR]
Detail
Get status if Shutter can be controlled by key on the top panel
Response Acceptable
“000_%1” [CR]
%1
“ON” - Shutter is not controllable by key on the top
panel
“OFF” - Shutter is controllable by key on the top
panel
Unacceptable
“?” [CR]
9.10.15 CR_SHUTH Command
Command
“CR_SHUTH” [CR]
Detail
Get time setting to start the shutter management
Response Acceptable
“000_%1” [CR]
%1
“005” -
5 minutes
006” - 6
minutes :
179” - 179
minutes
180” - 180
minutes
Unacceptable
“?” [CR]
9.10.16 CR_SECURITY Command
Command
“CR_ SECURITY” [CR]
Detail
Get ON/OFF setting status of Security on menu.
Response Acceptable
“000_%1” [CR]
%1
“ON” - PJ is locked
“OFF” - PJ is not locked.
Unacceptable
Error Code” [CR]