Status Read Commands
8-2 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
8.3 Operation Requirements
When the projector status is in the status below, Functional Execution Commands are limited. Status
Read Commands are available in following statuses:
Projector Status Available Functional Execution Command
In Standby Mode C00: POWER ON
Count Down in process C00: POWER ON (Countdown is terminated)
Cooling Down in process NONE (No Execution)
Cooling Down in process due to abnormal temperature NONE (No Execution)
In Abnormal Temperature NONE (No Execution)
Power Failure (60 seconds after Power failed) NONE (No Execution)
Power Saving Cooling Down in process NONE (No Execution)
In Power Saving status C00: POWER ON C01: POWER OFF
Note: An appropriate error code is returned when the projector receives other command in the above status.
8.4 Image Command
8.4.1 CF_ CONT Command
Command
“CF_CONT_%1” [CR]
%1
“000-063”- Directly specify setting value of Contrast
UP”- Increment setting value of Contrast by 1
DN”- Decrement setting value of Contrast by 1
Detail
Set user controlled value of Contrast (available only in the normal
Power ON status).
The value set by this command is not stored in the projector.
Therefore, when the power is turned to ALL OFF status, the value
returns to the original setting. (It is stored in Suspend mode.)
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.4.2 CF_ BRIGHT Command
Command
“CF_BRIGHT_%1” [CR]
%1
“000-063” - Directly specify setting value of Brightness
UP” - Increment setting value of Brightness by 1
DN” - Decrement setting value of Brightness by 1
Detail
Set user controlled value of Brightness (available only in the normal
Power ON status).
The value set by this command is not stored in the projector’s
memory. Therefore, when the power is turned to ALL OFF status, the
value returns to the original setting. (It is stored in Suspend mode.)
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]