Christie LW600 User Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
Status Read Commands
8-18 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
8.7.2 CF_DZCENT Command
Command
“CF_DZCENT_%1” [CR]
%1
“CENT” - Cancel Digital Zoom (CENT: “CENTER”)
Detail
Cancel Digital Zoom mode (valid only when in the normal Power ON
status and Input for Computer is selected).
Response Acceptable
“000” [CR]
Unacceptable
“101” [CR] - When input is Video
8.7.3 CF_KEYSTONE Command
Command
“CF_KEYSTONE _%1” [CR]
%1
“UP” - Correct Keystone distortion to reduce upper part of image
FUP” - Correct Keystone distortion to reduce upper part
DN” - Correct Keystone distortion to reduce lower part of image
FDN” - Correct Keystone distortion to reduce lower part largely
LEFT” - Correct Keystone distortion to reduce left part of image
FLFT” - Correct Keystone distortion to reduce left part largely
RIGHT” - Correct Keystone distortion to reduce right part of image
FRGT” - Correct Keystone distortion to reduce right part largely
RST- Set Keystone OFF
Detail
Change level of Keystone distortion correction (available only in the
normal Power ON status). When the limit of the correction level is
reached, the projector accepts the command but does not execute it.
Receiving this command immediately invokes the operation. When
you try to set the value beyond available range, the error code “201”
is returned and the operation is not executed.
Example 1: When the correction level of the right part has reached
its upper limit and then the command “RIGHT” is received.
Example 2: When the upper part correction allows only another step,
and then the command “FUP” is received.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.7.4 CF_KEYSTONEMODE Command
Command
“CF_KYSTNMODE _%1” [CR]
%1
“STR” - Set Keystone store mode to Store
RST- Set Keystone store mode to Reset
Detail
Set Keystone store mode (Available only in the normal Power ON
status)
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]