Page view 17
2-8 CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
Section 5: Parts and Module Replacement
2.5.2 LENS FLAGS
1. Remove the lens. Refer to 2.5.1 Lens, on page 2-7.
2. Use a #1 Phillips™ screwdriver to remove the 2 M2 x 4mm screws and lock washers securing the
lens flag to the lens.
3. Position the replacement flag (#012-101504-xx) so it is centered between the 2 mounting positions
(Figure 2-2).
4. Use a #1 Phillips™ screwdriver to install the supplied M2 x 4mm screws (#012-100031-xx) to
secure the flag to the lens.
5. Manually rotate the lens to ensure there is no interference. If the lens does not rotate easily the lens
itself or the motors may be damaged.
6. Reinstall the lens. Refer to 2.5.1 Lens, on page 2-7
.
7. Perform lens calibration using either the CDP or web ui. For details, refer to the CP2000-M/MR
User Manual (020-100123-xx).
NOTES: 1) All lens types use the same lens flag for both zoom and focus (#021-101504-xx). 2) All
lenses have a zoom and focus lens flag, except for the 1.05:1 lens, which only has 1 flag for focus.
FIGURE 2-2 REPLACING LENS FLAGS