Page view 51
Status Read Commands
8-24 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
8.8.2 CF_LAMPMODE Command
Command
“CF_LAMPMODE_%1” [CR]
%1
“FULL” - Set lamp mode to 2-lamp (FULL)
HALF” - Set lamp mode to 1-lamp (HALF)
Detail
Select Lamp mode (valid only when in the normal Power ON status).
The value set by this command is stored in EEPROM, and the setting
remains effective after the power is turned to ALL OFF status. In Half
mode, one lamp with a lesser-used time lights automatically.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.8.3 CF_AUTOLAMPCONTRL Command
Command
“CF_AUTOLAMPCONTRL_%1” [CR]
%1
“NORMAL” - Set lamp control mode to NORMAL
ECO” - Set lamp control mode to ECO
AUTO” - Set lamp control mode to AUTO
Detail
Select Lamp control mode (valid only when in the normal Power ON
status).
The value set by this command is stored in EEPROM, and the setting
remains effective after the power is turned to ALL OFF status.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]