Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 8-31
020-000046-02 Rev 2 (07-2011)
8.9.14 CF_FILCTL Command
Command
“CF_FILCTL_%1” [CR]
%1
“ROLL” - Execute operation of scroll of filter
Detail
Execute operation of scroll of filter
Response Acceptable
Acceptable
Unacceptable
Unacceptable
8.9.15 CF_FILSCRL Command
Command
“CF_FILSCRL_%1” [CR]
%1
“RST” - Reset Filter scroll counter
Detail
Reset Filter scroll counter
Response Acceptable
Acceptable
Unacceptable
Unacceptable
8.9.16 CF_TESTPAT Command
Command
“CF_TESTPAT_%1” [CR]
%1
“COLOR” - Display Color bar
“GRAD1” - Display 16step(white→black)
“GRAD2” - Display 16step(white←black)
“GRAD3” - Display 16step(white↓black)
“GRAD4” - Display 16step(white↑black)
“WHITE” - Display all white
“BLACK” - Display all black
“CROSS” - Display Cross
“OFF” -Do not show test pattern display
“UP” - Switch forward
“DN” - Switch backward
Detail
Execute test pattern display (available only in the normal Power ON
status).
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.9.17 CF_FDEFAULT Command
Command
“CF_FDEFAULT_%1” [CR]
%1
“RST”
Detail
Return the settings to Factory Default status (valid only when in the
normal Power ON status).
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]