Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 8-25
020-000046-02 Rev 2 (07-2011)
8.9 Setting Commands
8.9.1 CF_LANG Command
Command
“CF_LANG_%1” [CR]
%1
“ENG” - Select ENGLISH
“DEU” - Select German
“FRA” - Select French
“ITA” - Select Italian
“ESP” - Select Spanish
“POR” - Select Portuguese
“NED” - Select Dutch
“SVE” - Select Swedish
“JPN” - Select Japanese
“CHI” - Select Chinese
“KOR” - Select Korean
“RUS” - Select Russian
Detail
Select language for OSD (valid only when in the normal Power ON
status).
The language set by this command is stored in EEPROM and the
setting remains effective after the power is turned to ALL OFF
status.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.9.2 CF_DISP Command
Command
“CF_DISP_%1” [CR]
%1
“ON” - Set Display to ON
“CNTDWNOFF” - Set Display to Count down Off
“OFF” - Set Display to OFF
“UP” - Switch forward (On → Count down Off → Off → On → -)
“DN” - Switch backward (On → Off → Count down Off → On → -)
Detail
Set/Cancel Display (valid only when in the normal Power ON status).
The value set by this command is stored in EEPROM, and the setting
remains effective after the power is turned to ALL OFF status.
Response Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]