Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 9-7
020-000046-02 Rev 2 (07-2011)
“?” [CR] - When unknown command is received
9.5.4 CR_V-POS Command
Command
“CR_V-POS” [CR]
Detail
Get value of Vertical Position
Response Acceptable
“000_%1” [CR]
%1
“0000” – “ nnnn”
(nnnn = Total Line - Display Area V)
Unacceptable
“Error Code” [CR] - When command is invalid in the
given condition (such as being selected input)
“?” [CR] - When unknown command is received
9.5.5 CR_CLAMP Command
Command
“CR_CLAMP” [CR]
Detail
Get value of Clamp
Response Acceptable
“000_%1” [CR]
%1
“0000” – “ 4095”
Unacceptable
“Error Code” [CR] - When command is invalid in the
given condition (such as being selected input)
“?” [CR] - When unknown command is received
9.5.6 CR_DDOTS Command
Command
“CR_DDOTS” [CR]
Detail
Get value of Display Dots
Response Acceptable
“000_%1” [CR]
%1
“0256”-”nnnn” (nnnn = Total Dots – Position H)
Unacceptable
“Error Code” [CR] - When command is invalid in the
given condition (such as being selected input)
“?” [CR] - When unknown command is received
9.5.7 CR_DLINE Command
Command
“CR_DLINE” [CR]
Detail
Get value of Display Line
Response Acceptable
“000_%1” [CR]
%1
“0100” – “nnnn”
(nnnn = Total Line – Position V)
Unacceptable
“Error Code” [CR] - When command is invalid in the
given condition (such as being selected input)
“?” [CR] - When unknown command is received