Status Read Commands
9-2 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
9.4.2 CR_BRIGHT Command
Command
“CR_BRIGHT” [CR]
Detail
Get user controlled value of Brightness
Response Acceptable
“000_%1” [CR]
%1
“000” – “063”
Unacceptable
“?” [CR]
9.4.3 CR_COLOR Command
Command
“CR_COLOR” [CR]
Detail
Get user controlled value of Color
Response Acceptable
“000_%1” [CR]
%1
“000” – “063”
Unacceptable
“Error Code” [CR] -When command is invalid in the
given condition (such as being selected input)
“?” [CR] - When unknown command is received
9.4.4 CR_TINT Command
Command
“CR_TINT” CR]
Detail
Get user controlled value of Tint
Response Acceptable
“000_%1” [CR]
%1
“000” – “063”
Unacceptable
“Error Code” [CR] -When command is invalid in the
given condition (such as being selected input)
“?” [CR] - When unknown command is received
9.4.5 CR_APCTRL Command
Command
“CR_APCTRL” [CR]
Detail
Get setting status of Auto Picture Control
Response Acceptable
“000_%1” [CR]
%1
“L1” - Operate Auto Picture Control with Level1
“L2” - Operate Auto Picture Control with Level2
“OFF” - Set Auto Picture Control OFF
Unacceptable
“?” [CR]