Status Read Commands
9-22 LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)
9.9 Lamp Status Read Commands
9.9.1 CR_LAMPREPL Command
Command
“CR_LAMPREPL” [CR]
Detail
Get the information of Lamp Replacement time
Response Acceptable
“000_%1” [CR]
%1
“2**” 2 - indicates 2 lamps are used in this model.
*- indicates the status of each lamp in lamp number
order.
“Y” means the lamp operating time is over the
threshold for lamp replacement, and
“N” means it has not reached to. e.g.
“2YN” - This indicates it is 2-lamp system, and
Lamp #2 has not been reached to the replacement
time while #1 should be replaced.
Unacceptable
“?” [CR]
9.9.2 CR_LAMPMODE Command
Command
“CR_LAMPMODE” [CR]
Detail
Get Lamp mode setting status
Response Acceptable
“000_%1” [CR]
%1
“FULL” - Lamp mode is set to 4-lamp (FULL)
“HALF” - Lamp mode is set to 2-lamp (HALF)
Unacceptable
“?” [CR]
9.9.3 CR_AUTOLAMPCONTRL Command
Command
“CR_AUTOLAMPCONTRL” [CR]
Detail
Get selected Lamp control mode
Response Acceptable
“000_%1” [CR]
%1
“NORMAL” - NORMAL is selected.
“ECO” - ECO is selected.
AUTO - AUTO is selected.
Unacceptable
“Error Code” [CR]