Status Read Commands
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information 10-1
020-000046-02 Rev 2 (07-2011)
10 Command with Address Specification
10.1 Overview
Commands with address are used to remote control more than one projector through RS-232C by a
computer.
The command with address is defined as a single command per line that starts with “A” and ends with
carriage return (0x0D).
When a projector receives carriage return (0x0D), it starts decoding.
An address such as “A001” is prefixed to the Basic Serial Command or Expand Serial Command
already mentioned.
Functional Execution Command: Example: “A001C05” [CR]
Status Read Command: Example: “A001CR0” [CR]
The projector can set up its own address in Service mode.
The initial setting value is “No.001”
Available range of the value is “001” to “999”
The projector clears the data in the receive buffer in the following cases.
When receiving LF (0x0A) or EOF (0x1A)
When it takes more than one second to receive a single command. (Until receiving carriage return
after the reception of the first data)
The projector returns a response within 60ms.